Magnolia Plastics Adhesives
Magnobond 6369
Plastics for the Space Age Since 1957
Magnobond 6369, Parts A & B
(Formerly 99-124, A and B)
DESCRIPTION
Magnolia 6369, Parts A and B, is a two part epoxy adhesive designed to have
excellent properties at elevated temperatures.
SPECIAL FEATURES
1. Long pot life.
2. Room Temperature or elevated temperature cure.
3. Excellent storage stability at room temperature.
PROPERTIES OF UNCURED MATERIAL
Color: Part A: Gray
Part B: Amber
Mix: Gray
Viscosity: Part A: Paste
Part B: Paste
Mix: Paste
Specific Gravity: Part A: 1.25 Part B: 0.93 Mix: 1.24
Mix Ratio: 100 parts by weight A
17 parts by weight B
3 Ounce Pot Life @ 77°F: 75 minutes
Cure Schedule: 7 days at Room Temperature or
1-2 hours at 150-250°F
Shelf Life: 12 months at Room Temperature
SPI Classification: Part A: 4 Part B: 4
Freight Class: Part A: 1 Part B: 2
Flash Point: Part A: >200°F Part B: >200°F
CURED PROPERTIES
Lap Shear Strength, ASTM D1002, Aluminum to Aluminum
Test Temperature Test Value, psi
75°F 3,800
180°F 2,518
250°F 2,218
300°F 1,930
350°F 1,536
400°F 891
500°F 560
The above values were obtained using a cure schedule of 7 days at
room temperature. Specimens were soaked for 10 minutes at temperature
prior to testing.
Specimens were cured at room temperature for 7 days and soaked at 400°F
for 2 hours.
Lap Shears at 400°F 832 psi
Specimens were cured at room temperature for 7 days and soaked at 450°F
for 2 hours.
Lap Shears at 450°F 450 psi
Specimens were cured at 250°F for 1 hour and soaked at 400°F for
2 hours.
Lap Shears at 400°F 858 psi
Specimens were cured at 250°F for 1 hour and soaked at 450°F for
2 hours.
Lap Shears at 450°F 486 psi
CURED PROPERTIES
Lap Shear Strength, ASTM D1002, Aluminum to Aluminum
Test Temperature Test Value, psi
75°F 3,800
180°F 2,518
250°F 2,218
300°F 1,930
350°F 1,536
400°F 891
500°F 560
The above values were obtained using a cure schedule of 7 days at
room temperature. Specimens were soaked for 10 minutes at
temperature prior to testing.
Specimens were cured at room temperature for 7 days and soaked at
400°F for 2 hours.
Lap Shears at 400°F 832 psi
Specimens were cured at room temperature for 7 days and soaked at
450°F for 2 hours.
Lap Shears at 450°F 450 psi
Specimens were cured at 250°F for 1 hour and soaked at 400°F
for 2 hours.
Lap Shears at 400°F 858 psi
Specimens were cured at 250°F for 1 hour and soaked at 450°F
for 2 hours.
Lap Shears at 450°F 486 psi
DANGER FIRST-AID
-------------------------------- -------------------------
May cause severe irritation. Eyes - Immediately flush
Do not get in eyes, on skin eyes with plenty of water
or clothing. for at least 15 minutes.
Do not inhale vapors. Get medical attention.
Wear rubber gloves & aprons. Skin - Wash immediately
Use with adequate ventilation. with soap and water.
Wash thoroughly after handling. Clothing - Remove clothing
For industrial use only. and wash before reuse.
Keep container closed.
Do not reuse this container.
Spec Sheet Dated: 01/21/93
For more information, contact us at:
Sales Division
Magnolia Plastics, Inc.
5547 Peachtree Industrial Boulevard
Chamblee, GA 30341-2296 USA
770-451-2777, Voice
770-451-5376, FAX
800-831-8031, Voice
Email: sales@magnapoxy.com
How To Order:
Doing Business with Magnolia Plastics
Return to Magnolia Plastics Home Page
Copyright © 1996, Magnolia Plastics, Inc. All Rights Reserved, including
the right of reproduction in whole or in part in any form. The stylized Magnolia Plastics logo is a
regsitered trademark of Magnolia Plastics, Inc.
Contact Magnolia at sales@magnapoxy.com
Updated: September 26, 1996