Magnolia Plastics Adhesives
Magnobond 6394
Plastics for the Space Age Since 1957
Magnobond 6394, Parts A & B
Also Known As
Magnolia 99-058, Parts A & B
DESCRIPTION
Magnobond 6394, A & B and Magnolia 99-058, A & B are two part epoxy adhesives
giving good properties at elevated temperatures. These products are
non-metallic versions of Magnolia 6392.
PROPERTIES
Mix Ratio: 100:27 parts by weight
3 oz. Pot Life: 97 minutes at 77`F
Cure Schedule: 7 days room temperature or 1-2 hours
150-250`F
Note: At room temperature, most of the
curing process is completed during the first
12 to 24 hours.
Lap Shear Strength, ASTM D1002, Aluminum to Aluminum
Test Condition Result, psi
75`F 4,000
300`F 1,424
-67`F 3,666
30 days at 120`F and 100%
Relative Humidity 3,834
7 days in Hydraulic Oil 4,158
7 days in JP-4 4,070
Creep Rupture per MMM-A-132A
75`F - 1600 psi <0.005 inches
180`F - 800 psi <0.005 inches
Testing to FMS-4500A, Form 2 - Non-Metallic Filler
Test Values, psi
Test Conditions 5 day/R.T. Cure 2 hour/200`F Cure Requirement
10 minutes at -67`F 2,700 4,400 2,000
75`F 3,700 3,400 3,000
10 minutes at 200`F 2,100 2,600 2,000
10 minutes at 300`F 1,500 1,800 1,300
7 days water immersion
75`F 4,500 4,200 3,000
200`F 2,000 2,200 1,800
7 days condensing humidity
75`F 3,900 4,600 3,000
200`F 2,100 2,500 1,800
7 days MIL-L-7808 (Engine Oil)
75`F 4,100 3,600 2,700
200`F 2,300 2,600 2,000
7 days MIL-H-83282 (Hydraulic Oil)
75`F 4,200 3,500 2,700
200`F 2,300 2,300 2,000
7 days MIL-H-5606 (Hydraulic Oil)
75`F 3,800 3,700 2,700
200`F 2,500 2,400 2,000
7 days MIL-T-5624 (JP-4)
75`F 3,800 3,900 2,700
200`F 2,200 3,200 2,000
7 days MIL-A-8243 (Anti-icing)
Type I
75`F 5,000 3,600 2,700
200`F 3,200 2,100 2,000
Type II
75`F 5,000 3,600 2,700
200`F 2,700 2,400 2,000
DANGER FIRST-AID
-------------------------------- -------------------------
May cause severe irritation. Eyes - Immediately flush
Do not get in eyes, on skin eyes with plenty of water
or clothing. for at least 15 minutes.
Do not inhale vapors. Get medical attention.
Wear rubber gloves & aprons. Skin - Wash immediately
Use with adequate ventilation. with soap and water.
Wash thoroughly after handling. Clothing - Remove clothing
For industrial use only. and wash before reuse.
Keep container closed.
Do not reuse this container.
Spec Sheet Dated: 02/26/92
For more information, contact us at:
Sales Division
Magnolia Plastics, Inc.
5547 Peachtree Industrial Boulevard
Chamblee, GA 30341-2296 USA
770-451-2777, Voice
770-451-5376, FAX
800-831-8031, Voice
Email: sales@magnapoxy.com
How To Order:
Doing Business with Magnolia Plastics
Return to Magnolia Plastics Home Page
Copyright © 1996, Magnolia Plastics, Inc. All Rights Reserved, including
the right of reproduction in whole or in part in any form. The stylized Magnolia Plastics logo is a
regsitered trademark of Magnolia Plastics, Inc.
Contact Magnolia at sales@magnapoxy.com
Updated: September 26, 1996